=========================================================================== Release Notes - lightSTUDIO v2.5.0 (April 28, 2020) =========================================================================== * Supports new internal hardware for translational chart motion. =========================================================================== Release Notes - lightSTUDIO v2.4.9 (December 11, 2019) =========================================================================== * Bug fix: - Activate buttons in LED settings dialog after cancelling procedure. - Display progress bar during illuminants update procedure. =========================================================================== Release Notes - lightSTUDIO v2.4.8 (October 23, 2019) =========================================================================== * Bug fix: - Use now correct spectrometer settings in configuration file. * Improvement: - Better control of integration time editor in LED illumination dialog. - Log file is now written to: C:\Users\\AppData\Roaming\Image Engineering\Lightstudio Software does not need admin rights for logging functionality. - Update of old illuminant files for Lighthead-L does now work correctly after calibration procedure. =========================================================================== Release Notes - lightSTUDIO v2.4.7 (October 1, 2019) =========================================================================== * Bug fix in LED lighthead control panel. =========================================================================== Release Notes - lightSTUDIO v2.4.6 (September 12, 2019) =========================================================================== * Added input field for integration time of spectrometer. =========================================================================== Release Notes - lightSTUDIO v2.4.5 (June 28, 2019) =========================================================================== * Added input field for integration time of spectrometer. Now the value for the individual integration time from the acceptance protocol can be easily entered in the illumination dialog. This only applies to Lightstudio devices with iQ-LED V2 Lightheads. For all other Lightstudios the displayed value can be left unchanged. =========================================================================== Release Notes - lightSTUDIO v2.4.4 (June 14, 2019) =========================================================================== * Bug fix: Does not disconnect iQ-LED device anymore if there is an old calibration file available. Calibrations performed with software versions before 2.3.0 are not compatible with newer versions. * Changed spectrometer settings for iQ-LED version 2 to more suitable values. =========================================================================== Release Notes - lightSTUDIO v2.4.3 (April 2, 2019) =========================================================================== * The control light for measuring the illuminance for illuminance compensation in the LED settings dialog now uses the same light as in the iQ-LED software. Now there is only one illuminance value available in the acceptance protocol for the Lightstudio, which can be used for both programs. =========================================================================== Release Notes - lightSTUDIO v2.4.2 (January 28, 2019) =========================================================================== * Update of motor controller libraries. =========================================================================== Release Notes - lightSTUDIO v2.4.1 (January 17, 2019) =========================================================================== * Update of documentation files. * Bug fixes. * Added missing MSVC2015 installer to lightSTUDIO installer. * Added info buttons for spectrometer and iQ-LED devices. =========================================================================== Release Notes - lightSTUDIO v2.4.0 (January 11, 2019) =========================================================================== * Support of HDR box with LG4 devices. =========================================================================== Release Notes - lightSTUDIO v2.3.0 (November 29, 2018) =========================================================================== * The software now supports the iQ-LED lightHEAD-L V2. =========================================================================== Release Notes - lightSTUDIO v2.2.4 (October 31, 2018) =========================================================================== * Update of iQ-Standardlight API, which is used in lightSTUDIO software and CLI (Command Line Interface). Suppresses now dispensable warnings from USB interface in command line tool when CLI is used. =========================================================================== Release Notes - lightSTUDIO v2.2.3 (March 21, 2018) =========================================================================== * Changed minimum release time for iQ-Trigger to 0.1 seconds. =========================================================================== Release Notes - lightSTUDIO v2.2.2 (March 6, 2018) =========================================================================== * Bug fix: Does not display warning "Spectrometer not connected" anymore, which used to appear in "LED lightHEAD settings" after starting spectral calibration. This only occurred at first run of software. =========================================================================== Release Notes - lightSTUDIO v2.2.1 (February 5, 2018) =========================================================================== * Bug fix in usage of iQ-Trigger in sequence lists. * Removed unnecessary error messages when cancelling "Open..." and "Save as..." dialogs. =========================================================================== Release Notes - lightSTUDIO v2.2.0 (November 27, 2017) =========================================================================== - General: * Removed enforcement of admin rights for the usage of the software, all internal files and settings written by the software are stored in user's home directory now. * Minor bug fixes. * Replaced old address of Image Engineering with new one in document iQ-Trigger-API_terms_and_conditions. - LED lightHEAD functionality: * Added support for new Mini Spectrometer. * Removed enforcement to load initial illuminance measurement file. Added input field for this value instead, which is stored in the acceptance protocol. * Removed input fields for spectrometer integration time in the LED lightHEAD control panel. * Added display for current measurement of illuminance (lux) and Correlated Color Temperature (CCT) to spectrometer module. =========================================================================== Release Notes - lightSTUDIO v2.1.0 (November 23, 2016) =========================================================================== * Added command line interface (CLI) for lightSTUDIO-S as an integral part of the lightSTUDIO installer (lightSTUDIO-S_CLI.exe). * Improvement (lightSTUDIO-S CLI): Now based on iQ-Standardlight API and libusb * Improvement (lightSTUDIO-S CLI): Intensity is now set and get in percent between 0 and 100. * Improvement (lightSTUDIO-S CLI): Added a "setChannel" command * Improvement (lightSTUDIO-S CLI): Updated and reformatted help texts and the manual * Improvement (lightSTUDIO-S CLI): Now has the same version number as the main lightSTUDIO application =========================================================================== Release Notes - lightSTUDIO v2.0.11 (October 24, 2016) =========================================================================== * Bug fix (Motion module): Setting velocity to maximum value of 3.0 m/s provoked an error with current hardware controller. =========================================================================== Release Notes - lightSTUDIO v2.0.10 (August 10, 2016) =========================================================================== * Added temperature control for LED lightHEAD. =========================================================================== Release Notes - lightSTUDIO v2.0.9 (June 30, 2016) =========================================================================== * Bug fix (LED lightHEAD module): Program crashed, when stored lists for batch processing (.csv files) were opened with table entries for illuminants, that did not exist anymore. This could have happened for example if the illuminant files were deleted manually from the program directory or if a .csv file was opened for a different lightSTUDIO. Since illuminant files are device dependent, the latter case also lead to this error. * Improvement (LED lightHEAD module): It was able to create illuminants in the LED lightHEAD dialog without a current illuminance correction. Now it is not possible to create illuminants without previously importing the delivered file "IlluminanceCorrection.txt" or performing the illuminance measurement oneself with a luxmeter. =========================================================================== Release Notes - lightSTUDIO v2.0.8 (June 22, 2016) =========================================================================== * Bug fix (LED lightHEAD module): After calibrating the LED lightHEAD, all already existing illuminant files are updated now with the current calibration. * Bug fix (Moving option): When the safety clamp was released during batch mode, the movement stopped immediately, but the next command in the batch list (translation table) was executed. This does not appear any longer, no commands are sent to motor controller after safety clamp is released. =========================================================================== Release Notes - lightSTUDIO V 2.0.7 (May 20, 2016) =========================================================================== * Bug fixes in LED lightHEAD modules: Memory leak when using LED lightHEAD settings dialog multiple times during one session lead to unstable behaviour of some response dialogs. The warm-up time for the illumination used to measure the lux value in the LED lightHEAD settings panel was to short. This lead to imprecise lux calculations. Now the warm-up time is 10 seconds before measurement. The displayed lux value for an illuminant in the corresponding progress bar of the batch processing is now the nominal value instead of the true measured value, which might differ. =========================================================================== Release Notes - lightSTUDIO V 2.0.6 (March 23, 2016) =========================================================================== * Update of underlying iQ-Standardlight API to version 1.0.3 =========================================================================== Release Notes - lightSTUDIO V 2.0.5 (February 29, 2016) =========================================================================== * Changed USB controller driver to libusb (WinUSB). * Drivers, DLL libraries, installer and executables are now signed with an Image Engineering security certificate. =========================================================================== Release Notes - lightSTUDIO V 2.0.4 (November 11, 2015) =========================================================================== * Bug fix in Windows x86 version: Program does not crash anymore when quitting. * Improvement in display of spectral measurement =========================================================================== Release Notes - lightSTUDIO V 2.0.3 (June 25, 2015) =========================================================================== * Minor bug fixes. * Update of motor controller libraries: USB port connection error solved. Sometimes USB ports were out of order for the motor controller, when lightSTUDIOs were plugged into different USB ports at the same PC. =========================================================================== Release Notes - lightSTUDIO V 2.0.2 (December 19, 2015) =========================================================================== * Some bug fixes. * Improved display for spectral measurement. * Added button for importing illuminance calibration file in settings dialog. =========================================================================== Release Notes - lightSTUDIO V 2.0.1 (December 4, 2014) =========================================================================== * Bug fix: detection of connected devices improved. =========================================================================== Release Notes - lightSTUDIO V 2.0.0 (November 4, 2014) =========================================================================== * Added modules for LED lightHEAD and HDR option. * Added batch processing for DIGITUS, lightHEAD and HDR option =========================================================================== Release Notes - lightSTUDIO V 1.1.0 (October 10, 2014) =========================================================================== * Bug fixes * Added module for timecode display =========================================================================== Release Notes - lightSTUDIO V 1.0.0 (January 18, 2014) =========================================================================== * Initial release for lightSTUDIO with moving option and BASIC lightHEAD